Recently, in the official website mailbox of Dosin Hardware Electronics, it was found that many customers are inquiring about "what factors are related to the corrosion of M12 connectors". In order to let everyone better understand M12 connectors, this article is specially organized. , to share with everyone.
In the industrial field, the M12 connector is used very frequently. When we put the M12 connector in a humid environment, the M12 connector will be corroded for a long time, and the product performance will appear correspondingly after the corrosion. question. In a particularly severe environment, the connection pins in the M12 connector socket may even rot all over, which is unacceptable for customers. So what are the factors related to the corrosion of M12 connectors? Next, Dosin Hardware and Electronic Engineers will come to popularize the reasons for the corrosion of M12 connectors.
1. Vibration When placed in an extreme vibration environment, the standard M12 connector will react. Over time, the plug-to-socket connection will gradually wear down and the pins will dent at the connection point, reducing reliability. Moreover, after such wear, further corrosion can be caused by exposure to steam;
2. The sources of electromagnetic interference with severe electromagnetic interference usually include production equipment and power channels adjacent to the channel. Machines and electrical paths generate electric fields that can couple into the paths causing noise and disrupting signal integrity;
3. Extreme temperature M12 connectors can generally endure a temperature difference of -10 to 60 degrees, which is no problem for most office and general industrial environments. However, if placed in an extremely harsh temperature environment, the temperature outside the range can lead to management errors and reliability problems;
4. Corrosive materials are often encountered in industrial environments with corrosive gases and liquids. Substances like oil, gas and chemicals can attack the outer M12 connector cover, the metal feet of the plug and socket, the cable jacket, etc.
After reading the above, you should have a deeper understanding of "what factors are related to the corrosion of M12 connectors". For more knowledge about the corrosion of M12 connectors, Dosin M12 connector engineers will continue to edit and publish them in The sensor connector topic is shared with you. Dosin Hardware Electronics, a large number of high-quality M12 connectors, M12 adapters, M12 wire harnesses and other products are waiting for you to choose. All M12 connector products have passed CE and ROHS certification and meet European environmental protection requirements. If you have M12 connectors to purchase For customized needs, please call us at 400-6263-698 for consultation.