RD6006/RD6006-W LED Switching Power Supply S-400W-48V/DC12/24/36/60V 8.3A-33.3A Support Monitoring Transformer Lighting

$35.80
SKU: EB0045197
Copy to clipboard
82 Sales
0 reviews
In Stock Availability
Bulk Purchase, Auto Savings:
$34.19
10-19 PCS
$32.39
20-99 PCS
$28.79
100+ PCS
Deliver to United States
Flat Shipping Rate $10.00
- +


Note: This power supply can be used with Product ID: 1587151 (RD6006/RD6006-W)S06A Case Product ID 1587330 (If you need to use with RD6006/RD6006-W, please select 60V)
Model: S-400-xx
Output power: 400W
Output voltage: DC12/24/36/48/60V (Optional)
Input voltage: 110V/220V AC
Ambient temperature: -10 ° C ~ +50 ° C
Adjustable voltage: ±10%
Product size: 215 x 115 x 50mm

ItemTechnical Specifications
OutputDC voltage12V24V36V48V60V
Rated current33.3A16.6A11.1A8.3A6.6A
Rated power399.6W398.4W399.6W398.4W396W
Ripple and noise ①<150mV  <150mV<240mV<240mV<240mV
Voltage accuracy±1%
Output voltage adjustment range±10%
Load Regulation<±1.2%<±1%<±0.5%<±0.5%<±0.5%
Linear adjustment rate<±1%
InputVoltage range90-132VAC/180-264VAC 47Hz~63Hz; 254VDC~370VDC
Efficiency (typical) ②>82%>84%>86%>86%>86%
Working current<5.2A 115VAC, <2.8A 230VAC
Electric shock110VAC: 25A, 220VAC: 50A
Start, rise, hold time200ms, 50ms, 20ms: 230VAC
ProtectionOverload protection105%-135% type: constant current output, +V0 falls to undervoltage point to cut off output, reset: power on again
Overvoltage protectionTurn off output when >=115%-145%
Undervoltage protectionTurn off output when <10%-45%
Short circuit protectionClose output
 Over temperature protectionRTH3:>=65°C fan starts, <=55°C fan off, >=80°C off output (5V-15V)
RTH3:>=70°C fan starts, <=60°C fan off, >=85°C off output (18V-48V)
EnvironmentWorking temperature, humidity-10°C ~+50°C, 20% ~90%RH
Storage temperature, humidity-20°C ~+85°C, 10%~95%RH
SafetyWithstand voltageInput-Output: 1.5KVAC 
Input - Enclosure: 1.5KVAC 
Output - Enclosure: 0.5KVAC for 1 minute
Leakage currentInput-output <6mA at 1.5KVAC
Leakage currentInput-output <1.5mA at 220VAC
Isolation resistanceInput-output, input-housing, output-housing: 500VDC/100MΩ
OtherSize215*115*50mm
Net reset / gross reset874.1/936.3g

①Ripple and noise measurement method: Use a 12mm twisted pair cable, and the terminal should be connected with 0.1uF and 47uF capacitors in parallel and measure at 20MHz bandwidth.
②Efficiency is tested at an input voltage of 230VAC, rated load, and ambient temperature of 25°C.
Accuracy: Includes setting error, linear adjustment rate and load adjustment rate.
Linear Rate Test Method: Test from low voltage to high voltage at rated load.
Load regulation test method: from 0% to 100% of rated load.
The startup time is measured in the cold start state. The fast and frequent switching machine may increase the startup time. When the operating altitude is higher than 2000M, the operating environment temperature should be reduced by 5°C/1000M.

see more

Contact Sales

RD6006/RD6006-W LED Switching Power Supply S-400W-48V/DC12/24/36/60V 8.3A-33.3A Support Monitoring Transformer Lighting
EB0045197
Your Name*
Your Email*
Topic*
Qty
Message
SUBMIT
Pay with Ease
American Express Apple Pay Diners Club Discover Mastercard Visa
Trusted Delivery
Trusted Delivery Image
If the price of the product is reduced within 30 days, we will notify you via email, SMS and mobile client~
Notify you when the item is below the price
Mobile phone number
Email address
If the goods arrive within 30 days, we will notify you via email, SMS and mobile client~
Mobile phone number
Email address
BULK-BUY