- This programmable control board is designed with 3-channel relays.
- It supports time delay/interlock/self-latching/sequential starting.
- The module is powerful and convenient to operate.
- There are six kinds of commonly used functions to meet the demand of more applications.
- It can be used to control solenoid valves, pumps, motors, light belt, etc.
Specification:
Model: YYS-4
Input voltage: DC/AC 7V~30V
Output power: Can control DC or AC loads within 5A
Time range: Adjustable from 0.1 seconds to 999 minutes
Wiring:
1. AC/DC: Input power supply DC/AC 7V~30V
2. IN1: Signal input 1 (negative trigger)
3. IN2: Signal input 2 (negative trigger)
4. IN3: Signal input 3 (negative trigger)
5. NO: relay normally open interface, relay are disconnected before energized, and connected to COM after energized.
6. COM: relay COM interface
7. NC: relay normally closed interface, connected to COM before relay is energized, and disconnected after relay is energized.
Functions:
Function can be set freely by user;Set parameters can be saved after power failure.
P--1: send signal 1, relay 1 is energized till A time automatically stop;
send signal 2, relay 2 is energized till B time automatically stop;
send signal 3, relay 3 is energized till C time automatically stop;
There is only one relay at work at the same time.
P--2: send signal 1, relay 1 is energized till A time automatic stop, then relay 2 is energized till B time stop, then relay 3 is energized till C time stop;Send signal 1 again, repeat the former action.
Send signal 2, relay 1 is energized till A time automatic stop, then relay 2 is energized till B time stop, then relay 3 is energized till C time stop;then relay 1 is energized till A time stop...an infinite cycle.
Send signal 3, relay 1 is energized for 100ms then stop, wait A time;  relay 2 is energized for 100ms then stop, wait B time;  relay 3 is energized for 100ms then stop, wait C time;  relay 3 is energized for 100ms then stop, wait A time;  relay 1 is energized for 100ms then stop... an infinite cycle.
P--3: After powered on,  relay 1 is energized for A time then stop, wait C time;relay 2 is energized for B time then stop, wait C time;Relay 1 and relay 2 work in turn;During the period of relay 1 and relay 2 are energized, relay 3 stops;During the period of relay 1 and relay 2 are de-energized,relay 3 is energized;
P--4: send signal 1, relay 1 will be energized after a delay of A time, then relay 2 will be energized after a delay of B time, and then relay 3 will be energized after a delay of C time;
send signal 2, relay 1 will be de-energized after a delay of A time, then relay 2 will be de-energized after a delay of B time, and then relay 3 will be de-energized after a delay of C time;
send signal 3, emergency reset signal;
P--5: send signal 1, relay 1 would work;send signal 1 again, relay stops; sending signal 2, 3 is respectively corresponding to each relay action; 3 channels are independent from each other.
P--6: send a signal 1, relay would work, while other relays stop;send signal 1 again, relay stops;sending signal 2, 3 is respectively corresponding to each relay action;There is only one relay at work at the same time.
Button setting instructions:
After powered on, it shows "----" to enter standby state;
press K1,
screen display: P--1: K2 and K3 adjust mode
Press K1 again, screen display: A001: K2 and K3 adjust the first time A, K4 adjust decimal point (time units)
Press K1 for the third time, screen display:B001: K2 and K3 adjust the second time B, K4 adjust decimal point (time units)
Press K1 for the forth time, screen display:C001: K2 and K3 adjust the third time C, K4 adjust decimal point (time units)
Press K1 for the fifth time, it shows "----" to enter standby state;
Decimal point and unit of time:
XX.X: The decimal point in the "tens" position,  timing range: 0.1 seconds ~ 99.9 seconds.
XXX: No decimal point, timing range: 1 second~9999 seconds.
XXX.: The decimal point in the units position, timing range:1 minute ~ 999 minutes.
see more

Contact Sales

YYS-4 3 Channel Programmable Relay Control Module Trigger Delay/Timer/Self-latching/Interlock Switch
EB0045775
Your Name*
Your Email*
Topic*
Qty
Message
SUBMIT
Tags: Relay
Pay with Ease
American Express Apple Pay Diners Club Discover Mastercard Visa
Trusted Delivery
Trusted Delivery Image
If the price of the product is reduced within 30 days, we will notify you via email, SMS and mobile client~
Notify you when the item is below the price
Mobile phone number
Email address
If the goods arrive within 30 days, we will notify you via email, SMS and mobile client~
Mobile phone number
Email address
BULK-BUY